If your chimney already has a liner ensure that it is of an adequate size for your stove.
Pellet stove venting in existing chimney.
Rigid l vent pipe can be installed to the chimney special adapters will allow a 4 stainless steel flexible pipe to be installed up the chimney.
How to vent a pellet stove through a masonry chimney chimney preparation.
Install a chimney liner.
Before you install your pellet stove or its vent have your chimney inspected and cleaned by a.
Yes your pellet stove can be vented through your existing chimney providing your pellet stove is placed in front of your existing fireplace and you have the proper clearance the airspace between the stove the walls and you meet the minimums as defined in the owner s manual.
Vertical run with a masonry chimney a less common type of vertical run is where a pellet stove uses an existing masonry chimney.
Horizontal venting for a pellet stove horizontal venting is the simplest and cheapest way to remove the exhaust gases from your pellet stove.
It requires a clay flue and a clay or metal thimble that connect the vent pipe of the pellet stove to the chimney.
This is a metal.
How to install a pellet stove through the chimney first get a chimney inspection.
Stove dealers often offer installation for a reasonable cost and local codes may require you to use a professional.
The vent pipe is connected to an adapter at the back of the stove then run out through the wall adapter plate to a distance of at least six inches from the exterior wall.
If you are installing a pellet stove insert which fits into a fireplace it is best to hire a fireplace professional to clean the chimney run the venting up through the chimney and provide a waterproof storm collar and chimney cap at the top.
Most pellet stove manufacturers no longer recommend using a short connection to a chimney without a liner because of the difficulties of thoroughly cleaning the vent once the stove is installed.
If you plan to replace a wood burning stove with a pellet model another venting option is to use the existing chimney for the wood stove.
All pellet stoves require a rainproof cap at the top.
Never use pvc pipe gas vent pipe dryer vent pipe or single wall black stove pipe to vent your pellet stove.
Below is a screen shot of the manual harman pellet stove regarding a chimney install.
Installing a pellet stove pipe in an existing chimney requires a chimney liner.
The chimney is in good condition with the clay tile liner so according to the manufacturer an install without a liner should be ok.
This system usually works by positioning the pellet stove directly in front of the chimney.
Your dealer can help you evaluate your best venting option.